Water turbine types

If you are looking for Water Turbine Types, then you are on the right page. It contains the water turbine for sale. Suppose you want to know the water turbine definition and types instead. Then this article is what you need.

In this post, we will discuss the types of water turbine pumps and water turbine and their types. There are two main water turbine types: impulse and reaction,as described above. The type of hydropower turbine selected for a project is based on the height of standing water—referred to as “head”—and the flow, or volume of water, at the site. The most common type of impulse turbine is Pelton turbine.There are also Turgo turbine, Cross-flow turbine (also known as the Bánki-Michell turbine, or Ossberger turbine),Jonval turbine,Reverse overshot water-wheel,Screw turbine.On the other side,the most common reaction turbine is Francis turbine but there are also Kaplan turbine,Tyson turbine,Gorlov helical turbine.

water turbine types

water turbine for sale

Pelton turbine or wheel is an impulsive turbine used mainly for high head hydroelectric schemes.The Pelton wheel is among the most efficient types of water turbines.The fluid power is converted into kinetic energy in the nozzles.The total pressure drop occurs in the nozzle. The resulting jet of water is directed tangentially at buckets on the wheel producing impulsive force on them.

pelton-wheel.jpg

Figure 10:This figure is from Pelton’s original patent (October 1880).

pelton-turbine.jpg

Figure 11:Another Pelton turbine or wheel.
taken by:http://www.turbinesinfo.com/what-is-a-turbine/

3.1.1 Components

Pelton wheel has the following main components:

  • Nozzle
  • Runner and buckets
  • Casing
  • Breaking jet

1.Nozzle
Nozzle of a pelton wheel is a circular guide mechanism which guides the water to flow at the desired directions.It also regulate the flow of water. A conical or spear needle operates inside the nozzle in axial direction. The main purpose of the nozzle is to regulate the flow of water through nozzle.When the needle is pushed forward into the nozzle, it reduces area if jet. As a result the quantity of water through the jet is also reduced. Similarly if the spear is pushed back out of nozzle, it increases the area of nozzle and discharge increases.The movement of spear is regulated by hand or by automatic governing arrangement.

pelton%20wheel%20water%20turbine.jpg
ResSysPic3_350.jpg

Figures 12 and 13:Nozzles

taken by:http://www.earlmorse.org/steamboatingpages/steamhappens22turbine/turbine.htm

http://www.canyonhydro.com/micro/microoptions.html

2. Runner and buckets

The runner is a circular disk carrying number of cup-shaped buckets which are placed at equal spacing around its circumference. Runner is generally mounted on the horizontal shaft with bearings and the buckets are either casted integrally with the disk or fastened separately. Buckets are made up of cast iron, bronze or stainless steel. Inner surface of the buckets are polished to reduce frictional resistance to the water jet.

2.jpg

Figure 14:A runner with casted buckets.

3. Casing
Steel coverings provided over the runner of pelton wheel is known as casing. It does not play any hydraulic function,but is necessary to provide the runner against accident. It has the following functions:

  • It prevents accidents.
  • Minimize the wind losses.
  • stops splashing of water.
  • Facilitates to collect water.
  • Transmission of water to the tail race.

4. Breaking jet
Whenever the turbine has to be brought to rest the nozzle is completely closed. But the runner of pelton wheel goes on revolving due to inertia. To bring the runner to rest in short time, a small nozzle is provided in such a way that it will direct the jet of water on the back of buckets. It acts as a brake for reducing the speed of the runner.

water turbine definition and types

3.1.2 Function

Nozzles direct forceful, high-speed streams of water against a rotary series of spoon-shaped buckets, also known as impulse blades, which are mounted around the circumferential rim of a drive wheel.As the water jet impinges upon the contoured bucket-blades, the direction of water velocity is changed to follow the contours of the bucket. Water impulse energy exerts torque on the bucket and wheel system, spinning the wheel,the water stream itself does a “u-turn” and exits at the outer sides of the bucket, decelerated to a low velocity. In the process, the water jet’s momentum is transferred to the wheel and thence to a turbine. Thus, “impulse” energy does work on the turbine. For maximum power and efficiency, the wheel and turbine system is designed such that the water jet velocity is twice the velocity of the rotating buckets. A very small percentage of the water jet’s original kinetic energy will remain in the water, which causes the bucket to be emptied at the same rate it is filled and thereby allows the high-pressure input flow to continue uninterrupted and without waste of energy. Typically two buckets are mounted side-by-side on the wheel, which permits splitting the water jet into two equal streams. This balances the side-load forces on the wheel and helps to ensure smooth, efficient transfer of momentum of the fluid jet of water to the turbine wheel.

taken by: http://en.wikipedia.org/wiki/Pelton_wheel#Function

Pelton_Turbine.jpg

Figure 15: Pelton wheel derives rotation from impulse force produced by the water jet.

taken by: http://www.learnengineering.org/2013/08/pelton-turbine-wheel-hydraulic-turbine.html

3.1.3 Applications

Pelton wheels are the preferred turbine for hydro-power, when the available water source has relatively high hydraulic head at low flow rates, where the Pelton wheel is most efficient. Thus, more power can be extracted from a water source with high-pressure and low-flow than from a source with low-pressure and high-flow, even when the two flows theoretically contain the same power. Also a comparable amount of pipe material is required for each of the two sources, one requiring a long thin pipe, and the other a short wide pipe. Pelton wheels are made in all sizes. There exist multi-ton Pelton wheels mounted on vertical oil pad bearings in hydroelectric plants. The largest units can be up to 200 megawatts. The smallest Pelton wheels are only a few inches across, and can be used to tap power from mountain streams having flows of a few gallons per minute. Some of these systems use household plumbing fixtures for water delivery. These small units are recommended for use with 30 feet (9.1 m) or more of head, in order to generate significant power levels. Depending on water flow and design, Pelton wheels operate best with heads from 49–5,905 feet (14.9–1,799.8 m), although there is no theoretical limit.
http://en.wikipedia.org/wiki/Pelton_wheel#Applications

main-range_chart.jpg

Figure 16:Application range for Pelton turbine(also for Turgo and Francis)

taken by:http://www.gilkes.com/Pelton-Turbines

3.2 FRANCIS TURBINE

The Francis turbine is a reaction turbine where water changes pressure as it moves through the turbine, transferring its energy. A watertight casement is needed to contain the water flow.Generally such turbines are suitable for sites such as dams where they are located between the high pressure water source and the low pressure water exit. Francis turbines are the most common water turbine in use today. They operate in a water head from 40 to 600 m (130 to 2,000 ft) and are primarily used for electrical power production.

M_vs_francis_schnitt_1_zoom.jpg

Figure 17: Side-view cutaway of a vertical Francis turbine. Here water enters horizontally in a spiral shaped pipe (spiral case) wrapped around the outside of the turbine’s rotating runner and exits vertically down through the center of the turbine.

taken by: http://en.wikipedia.org/wiki/Francis_turbine

Francis_Turbine_complete.jpg

Figure 18:Francis turbine connected to a generator.

taken by: http://commons.wikimedia.org/wiki/File:Francis_Turbine_complete.jpg

3.2.1 Components

Francis turbine has the following main components:

  • Spiral casing.
  • Stayring and stay vanes.
  • Runner.
  • Draft tube.
1_3.jpg

Figure 19: Cross section of a Francis turbine.

1. Spiral casing
The spiral casing is the water conduit between the penstock and the regulating mechanism.The cross section through the spiral casing is continuously decreasing, the retardation in cross section causes an equal distribution of water into the guide vane cascade.In older designs the spiral casing was usually casted. For new designs it is commonly made by plate segments welded together. This has decreased the production cost and the transport expenses considerably without noticeably decreasing the efficiency.For vertical axis Francis turbines the spiral casing is usually embedded in concrete for increased support.

2. Stayring and stay vanes
The stay ring consist of an upper and lower ring connected by welded stay vanes.The stay vanes purpose is to absorb the axial forces on the inside of the spiral casing.The vanes are given a favourable hydraulic shape to affect the water flow minimally.

Stay_guide_vanes.png

Figure 20:Inside of a Francis Turbine.

taken by:http://www.learnengineering.org/2014/01/how-does-francis-turbine-work.html

3. Runner
The runner consists of a hub, a shroud and runner blades connecting them. The runner converts the energy in the water to rotating motion and torque. The torque is transferred to the turbine shaft through a bolted friction joint or a combined friction/shear joint. The runner can either be casted or welded. For a welded design the hub and shroud is usually cast and welded together with hot pressed plate vanes.The number of blades depends upon the operating head. Runners with higher head will require a higher number of blades, this is mainly because of strength consideration. Increasing the number of blades reduce the pressure loading on the blade which will help to avoid cavitation and also prevent separation at the runner inlet during low loads. An increase in the number of blades also leads to more contact surface through the runner and thereby an increase in the friction losses.The thickness of the runner blades has to be large enough to withstand the hydraulic forces the blade is exposed to.For high head Francis turbines it is preferred to shape the blade in such a way that the main part of the hydraulic energy is utilized at the beginning of the blade. In this area the pressure difference from the pressure to the suction side will be large and thereby also the forces on the blade. It is therefore usual to have an increased thickness of the blade near the inlet and let the blade get thinner towards the outlet.

2010012640152269.jpg

Figure 21: Runner of Francis Turbine Unit.

taken by:http://www.tbhic.cn/en/productview.asp?id=57

4. Draft tube
The draft tube is the water conduit from the runner to the outlet gate. Its purpose is to convert the kinetic energy at the runner outlet to pressure energy at the draft tube outlet. This is possible by leading the water through a channel with increasing cross section.The draft tube consists of a cone and a plate shroud. The draft tube cone is of welded plate design and normally consist of two parts, upper and lower cone. The upper part of the cone is mounted to the lower cover. The lower cone is normally designed as a dismantling piece. This is connected to the draft tube shroud by a flange.

3.2.2 Function

Water flows from the penstock into the spiral casing. In the spiral casing the water is distributed around the complete periphery. The water is then guided by the stay vanes and guide vanes in the correct angle towards the runner. The guide vanes are adjustable and can change the angle depending on the inlet and outlet conditions of the turbine, they are controlled by a governor servo motor. The runner transfers the energy from the pressure and velocity in the water to a rotational momentum. The water exits through a draft tube that extracts the remaining energy in the water.The torque produced in the runner is transferred to a power producing generator through a shaft.

turbin-francis.jpg?w=604

Figure 22:The function of a Francis Turbine.

taken by:http://engineeringinside.blogspot.gr/2013/11/francis-turbine-explanation.html

3.2.3 Applications

Francis turbines may be designed for a wide range of heads and flows. This, along with their high efficiency, has made them the most widely used turbine in the world. Francis type units cover a head range from 40 to 600 m (130 to 2,000 ft), and their connected generator output power varies from just a few kilowatts up to 800 MW.Large Francis turbines are individually designed for each site to operate with the given water supply and water head at the highest possible efficiency, typically over 90%.In addition to electrical production, they may also be used for pumped storage, where a reservoir is filled by the turbine (acting as a pump) driven by the generator acting as a large electrical motor during periods of low power demand, and then reversed and used to generate power during peak demand. These pump storage reservoirs, etc. act as large energy storage sources to store “excess” electrical energy in the form of water in elevated reservoirs. This is one of only a few ways that temporary excess electrical capacity can be stored for later utilization.

1275966164919_hz-fileserver3_2089574.jpg

Figure 23:Hydroelectric power plant using francis turbine.

taken by:http://syzjsd.en.alibaba.com/product/315463813-210167245 /old_hydro_power_plant_rebuild_with_new_water_turbine_generator_replace.html

main-range_chart.jpg

Figure 24:Application range for Francis turbine(also for Turgo and Pelton)

taken by:http://www.gilkes.com/Pelton-Turbines

3.3 ADVANTAGES AND DISADVANTAGES OF A FRANCIS TURBINE OVER A PELTON WHEEL

Advantages:

  • Variation in the operating load can be more easily controlled.
  • The ratio of maximum and minimum operating heads can be even two.
  • The operating head can be utilized even when the variation in the tail water level is relatively large when compared to the total head.
  • The mechanical efficiency of Pelton wheel decreases faster with wear than Francis turbine.
  • The size of the runner, generator and power house required is small and economical if the Francis turbine is used instead of Pelton wheel for same power generation.

Disadvantages:

  • Water which is not clean can cause very rapid wear in high head Francis turbine.
  • The overhaul and inspection is much more difficult comparatively.
  • Cavitation is an ever present danger.
  • The water hammer effect is more troublesome with Francis turbine.
  • If Francis turbine is run below 50 percent head for a long period it will not only lose its efficiency but also the cavitation danger will become more serious.

taken by: http://www.scribd.com/doc/34568800/Hydraulic-Turbine-I

3.4 OTHER TURBINES

As written above,there are also Turgo turbine, Cross-flow turbine Kaplan turbine,Tyson turbine,Gorlov helical turbine.

3.4.1Turgo impulse turbines

The Turgo turbine is an impulse turbine designed for medium head applications. These turbines achieve operational efficiencies of up to 87%. Developed in 1919 by Gilkes as a modification of the Pelton wheel, the Turgo has certain advantages over Francis and Pelton designs for some applications. Firstly, the runner is less expensive to make than a Pelton wheel while it does not need an airtight housing like the Francis turbines. Finally the Turgo has higher specific speeds and at the same time can handle greater quantum of flows than a Pelton wheel of the similar diameter, leading to reduced generator and installation cost.Turgo turbines operate in a head range where the Francis and Pelton overlap. Turgo installations are usually preferred for small hydro schemes where low cost is very important.

Turgo_turbine.png

Figure 25:Turgo turbine.

taken by:http://en.wikipedia.org/wiki/Turgo_turbine#mediaviewer/File:Turgo_turbine.png

Turgo turbine is an impulse turbine where water does not change pressure but changes direction as it moves through the turbine blades. The water’s potential energy is converted to kinetic energy with a penstock and nozzle.

3.4.2Crossflow turbine

Also called a Michell-Banki turbine a crossflow turbine has a drum-shaped runner consisting of two parallel discs connected together near their rims by a series of curved blades. A crossflow turbine always has its runner shaft horizontal (unlike Pelton and Turgo turbines which can have either horizontal or vertical shaft orientation). Unlike most water turbines, which have axial or radial flows, in a crossflow turbine the water passes through the turbine transversely, or across the turbine blades. As with a waterwheel, water enters at the turbine’s edge. After passing the runner, it leaves on the opposite side. Going through the runner twice provides additional efficiency. When the water leaves the runner, it also helps clean the runner of small debris and pollution. The cross-flow turbines generally operate at low speeds. Crossflow turbines are also often constructed as two turbines of different capacity that share the same shaft.The turbine wheels are the same diameter, but different lengths to handle different volumes at the same pressure.

220px-Ossberger_turbine.jpg

Figure 26:Crossflow turbine.

taken by:http://en.wikipedia.org/wiki/Cross-flow_turbine#mediaviewer/File:Ossberger_turbine.jpg

3.4.3Kaplan Turbines

The Kaplan turbine has adjustable blades and was developed on the basic platform (design principles) of the Francis turbine by the Viktor Kaplan in 1913. The main advantage of Kaplan turbines is its ability to work in low head sites which was not possible with Francis turbines.Kaplan turbines are widely used in high-flow, low-head power production.The Kaplan turbine is an inward flow reaction turbine, which means that the working fluid changes pressure as it moves through the turbine and gives up its energy. The design combines radial and axial features. The inlet is a scroll-shaped tube that wraps around the turbine’s wicket gate. Water is directed tangentially through the wicket gate and spirals onto a propeller shaped runner, causing it to spin. The outlet is a specially shaped draft tube that helps decelerate the water and recover kinetic energy. The turbine does not need to be at the lowest point of water flow, as long as the draft tube remains full of water. A higher turbine location, however, increases the suction that is imparted on the turbine blades by the draft tube that may lead to cavitations due to the pressure drop. Typically the efficiencies achieved for Kaplan turbine are over 90%, mainly due to the variable geometry of wicket gate and turbine blades. This efficiency however maybe lower for very low head applications. Since the propeller blades are rotated by high-pressure hydraulic oil, a critical design element of Kaplan turbine is to maintain a positive seal to prevent leakage of oil into the waterway. Kaplan turbines are widely used throughout the world for electrical power production. They are especially suited for the low head hydro and high flow conditions – mostly in canal based hydro power sites.

taken by: http://cdn.intechopen.com/pdfs-wm/40550.pdf

TPHV02P01_15B.jpg

Figure 27:Kaplan turbine.

Domestic Wind Turbines – The Basics

Households can now make use of wind power technology by installing micro turbines, also known as or small-wind or ‘microwind’ turbines. When the wind is strong enough it turns the blades of the turbine, generating electricity. The U.K. climate is ideal for wind harnessing technologies as 40% of the wind in Europe is experienced here, and in the right area you should be able to see substantial savings on your electricity bills.

Pole mounted domestic wind turbine
Pole mounted domestic wind turbine

There are two types of microwind turbine:

  • Building mounted: These systems are installed on your roof, and have a fairly small capacity, averaging 1-2kW
  • Pole mounted: These installations are freestanding and have a larger capacity of around 5kW-6kW

The Energy Saving Trust has calculated that in an ideal location a roof mounted micro-turbine system could reduce your electricity bills by around £350 a year. Your system could also be eligible to receive payments for the electricity you generate through the government’s Feed-In Tariff (FIT) scheme. Here’s how the scheme works:

  • You are paid a ‘Generation Tariff’ for each unit of electricity you generate, regardless of whether you use it or not, at a tariff rate that is fixed when you make an application for the scheme. The scheme then pays you starting from when you apply to the scheme, for 20 years. A pole mounted installation in an ideal location could receive £2,700 a year at current tariff values.
  • You are also paid an ‘Export Tariff’ for any generated electricity that you don’t use. The same pole mounted installation could receive £160 a year in export payments at current tariff values.
  • The electricity that you generate is free for you to use. If you use more electricity than your system is generating at any point you will be taking it automatically from the grid as you do now, which you will pay for. Overall, however, you will still save money on your electricity bill.
  • You can get a loan to cover the cost of installing your system by instead signing up to the Green Deal scheme. The loan is recovered via your energy bill, using the money you have saved on your energy bill by using the system. This means that the installation should not cost you any additional money.

Calculate your savings now!

How Domestic Wind Turbines Work

How a domestic wind turbine feeds electricity to your home and to the national grid
How a domestic wind turbine feeds electricity to your home and to the national grid
  • When the wind turns a wind turbine’s blades this movement drives the rotating shaft the blades are attached to. This shaft sits inside a generator. Inside the generator the shaft is surrounded by a magnetic field, so that when the shaft rotates it generates an electric current. In smaller turbines the blades can be attached directly to a generator with a magnetic field.
  • The electricity the turbine produces is DC electricity. This DC electricity passes through a device called an inverter, which connects the turbine and your home’s electrical system. It converts the DC electricity to AC electricity which can be used in your home.
  • The electricity the wind turbine generates can be fed directly into your home or stored in batteries. The turbines can be connected to the national grid so that you can export any surplus electricity and receive FIT payments for your electricity, or you can keep your turbine off the grid and store your surplus using batteries, though this arrangement won’t qualify for FIT payments.
  • If your turbine is connected to the grid, any surplus electricity is automatically exported to the grid, and if you use electricity from the grid this is also supplied to your system automatically.

The providers of the FIT scheme do not currently measure how many units of electricity you export, but for microwind turbine systems it is assumed to be 75% of the electricity you generate. The capacity of a microwind turbine system to generate electricity varies according to the individual system, and can be described in kilowatts (kW). This value can range from approximately 0 to 15. The average capacity of a house mounted system is 1-2kW and the average capacity of a pole mounted system is 5-6kW.

Whilst this measure is valuable, it does not fully describe the capacity of a turbine as the wind speeds at which this capacity is reached differ from turbine to turbine. This means that the Small Wind Turbine Performance and Safety Standard is also used. Contained within this standard is the BWEA Reference Annual Energy. This is the energy in kWh that the turbine will produce annually at a consistent wind speed of 5m/s at a set turbine height. A second value, the BWEA Reference Sound Levels give the noise level of the turbine from 25 and 60m away rounded up to the nearest decibel (dB).

Installing Microwind Turbines

When considering a microwind turbine installation it is essential that you accurately measure the wind speed of your specific location. The average annual wind speed required to make wind turbines worth the investment is a minimum of 5 metres per second (11 mph), which is not usually achieved in urban or suburban areas. This is because the wind speed in urbanised areas is usually reduced by by closely arranged buildings and trees. Nearby hills can also affect wind speed, as does whether you live in a valley or not.

Building mounted domestic wind turbine
Building mounted domestic wind turbine

It is strongly recommended that before you commission a microwind installation that you accurately measure your local wind speed by buying and fitting an anemometer (wind measuring instrument). You should leave this device to carry out measurements for at least three months but ideally you should leave it for a year to get a comprehensive overview of the wind levels your property is exposed to.

Domestic Wind Turbine Installation Checklist

There are a few important things to consider:

  • Building mounted or pole mounted: Building mounted systems have a lower capacity than pole mounted systems, meaning that they will generate less electricity and are cheaper to install
  • Whether you want to connect to the grid: Currently you will need to connect to the grid toreceive FIT payments. Contact your local DNO (District Network Operator) to arrange connecting your turbine to the grid
  • Whether your local area is prone to power cuts: When the power in an area fails all inverters connected to the grid are switched off, meaning that your system will stop working. You can install batteries with your turbine to provide a back-up electricity store – ask your installer for more information
  • Roof integrity: If you are intending to install a building mounted turbine it’s wise to consult your installer on whether your house is durable enough to support the turbine – they can be heavy and vibrate when in use
  • Planning permission: There are currently permitted development rights granted for domestic wind turbine systems in England, which should mean that you won’t need planning permission for your installation. However, the criteria for this are complex and there are varying needs for planning permission across the rest of the U.K. It is therefore wise to check the planning permissions for your installation with your local authority well in advance. You will have to supply a number of documents as well as paying an application fee of £150. It is a good idea to meet with a local planning officer before submitting your application so you know exactly what is required, as is consulting with any third parties such as neighbours who may be affected by your installation. Some installers will provide information and support with filling out planning applications
  • Environmental permissions: If your planned turbine is over 15m tall or you are planning to install two turbines you may be required to commission a bat or bird survey of the area
  • Your energy supplier: The larger energy companies have a legal obligation to be registered FIT suppliers but for smaller companies this is optional. Check with your energy supplier to see what they provide regarding FIT
  • Are you carrying out other building projects? You might be able to reduce the size of your installation bill by carrying out the work at the same time as any other building or landscaping work you are planning

Installation Time

The time your system will take to install will vary with your specific circumstances, particularly if you decide to carry out the installation at the same time as other building work.

Domestic Wind Turbine Installers

If you intend to apply to the FIT payments scheme you will need to ensure that your installation is carried out by an MCS accredited installer using parts that meet MCS standards. When your installer signs off your installation as being MCS compliant they will give you an MCS certificate that you will need when applying for the scheme. If you are financing your installation through the Green Deal you will need to instead use an authorised Green Deal installer.

Domestic Wind Turbine Costs

A standard 1kW building mounted turbine installation costs around £2000, with a 2.5kW turbine costing around £15,000 and a 6kW around £23,000 including installation costs.

Pole mounted domestic wind turbine
Pole mounted domestic wind turbine

Typically larger systems cost more to install but can generate more electricity, delivering you bigger energy savings and larger tariff payments. An average system working in a 5 m/s wind speed location can save you around £350 on your electricity bill and pay you £160 in Export Tariff payments and £2,700 in Generation Tariff payments every year. You will be paid these tariffs from the date you register for FIT payments for 20 years.https://googleads.g.doubleclick.net/pagead/ads?guci=2.2.0.0.2.2.0.0&us_privacy=1YNY&client=ca-pub-4631420095579283&output=html&h=15&slotname=6409949898&adk=4019539845&adf=3200023268&pi=t.ma~as.6409949898&w=728&lmt=1613417609&psa=1&channel=7299622441&url=https%3A%2F%2Fwww.diydoctor.org.uk%2Fprojects%2Fdomestic-wind-turbines.htm&flash=0&wgl=1&adsid=ChEIgNSogQYQmNm9wobVvZ-bARI9AKu7heg3v5j3N9BJyyEnVgy7qVQqv3GsM3IXqw-voIe-wO8g9U3GSrqOOcNaKSwxlorfuTo3pgD4cZd80g&dt=1613417594434&bpp=44&bdt=12248&idt=4056&shv=r20210211&cbv=r20190131&ptt=9&saldr=aa&abxe=1&cookie=ID%3Da46e6f01d9595ffe%3AT%3D1613417484%3AS%3DALNI_MZx0AYA6PGD4Bl0OK6qByxEsO6UfA&prev_fmts=0x0&prev_slotnames=9837170960&nras=1&correlator=2580623100149&pv_ch=7299622441%2B&frm=20&pv=1&ga_vid=2092623908.1613417596&ga_sid=1613417597&ga_hid=750009863&ga_fc=0&u_tz=60&u_his=1&u_java=0&u_h=800&u_w=1280&u_ah=732&u_aw=1280&u_cd=24&u_nplug=3&u_nmime=4&adx=79&ady=8854&biw=1265&bih=721&scr_x=0&scr_y=6809&eid=42530672%2C44736376%2C44736623%2C21068769%2C21068893&oid=3&psts=AGkb-H-Z3G_7-hRljTRsPqeAkVM-d6Ue0DuLqcHyHLlVWqIU2LT2TaEvAg&pvsid=3042850121677307&pem=618&ref=https%3A%2F%2Fwww.google.com%2F&rx=0&eae=0&fc=896&brdim=0%2C0%2C0%2C0%2C1280%2C0%2C1280%2C800%2C1280%2C721&vis=1&rsz=%7C%7CeEbr%7C&abl=CS&pfx=0&fu=8192&bc=31&jar=2021-02-15-19&ifi=2&uci=a!2&btvi=1&fsb=1&xpc=ZReE55zIJo&p=https%3A//www.diydoctor.org.uk&dtd=14797

The system will run for at least 20 years, and as the tariff value is set at the start of payments and index linked it is likely that the system will pay for itself in 7 years or less. After this point you will be receiving savings on your electricity bills and payments for around 13 years. For more information on the FIT scheme you can visit our Feed-In Tariff (FIT) page.

If you cannot afford to pay for the installation yourself the Green Deal scheme provides long term finance to cover all or part of your costs. These costs are recovered through your electricity bills using the savings you have made by using the turbine. Because the payment value should not exceed your saving this should mean that the installation doesn’t cost you additional money over what you would usually spend on your electricity bill. The scheme does include 7% interest in the payments however, so you will make more of a saving overall if you can afford to pay for the installation upfront. To find out more about the Green Deal, visit our Green Deal page.

In terms of maintenance, your installer will be able to give you specific guidance on any maintenance checks that need to be carried out. Usually it is recommended that you get your system professionally checked yearly at a cost of £100-£200. The turbine system comes with a lifetime warranty but the inverter may need replacing during that time at a cost of £1,000-£2,000 for larger systems. Any batteries used with the system will usually have to be replaced every 6-10 years.Find an MCS accredited local installer

The Benefits of Domestic Wind Turbines

An average household installing a well-sited domestic wind turbine system could benefit by over £3,200 a year. This includes the money you could save on your electricity bill as well as the Generation Tariff and Export Tariff payments you could receive from the FIT scheme. Our Feed-In Tariff scheme page contains more information on this new initiative. Domestic wind turbines deliver additional benefits:

  • Reduce your carbon footprint: A 6kW pole-mounted wind turbine system can save around 5.2 tonnes of CO2 a year.
  • Pays for itself quickly: Larger systems have a payback time of around 7 years at current tariff rates, meaning that your system’s payback time could be similar or less.

Leave a Comment